NY2


CoreSite’s NY2 data center is located in Secaucus, New Jersey and designed to offer businesses the ability to scale cost-effectively in a purpose-built facility while benefiting from an unbeatable ecosystem in CoreSite’s New York data center (NY1) in Manhattan. Built above the 500-year flood plain, CoreSite constructed this colocation facility from the ground up to ensure a secure, reliable and power-dense platform, capable of supporting a growing community of enterprises, domestic and international carriers, and leading cloud providers.
-
FACILITY SIZE
236,000+ sq. ft. of data center spaceDEPLOYMENTS
Cabinets, cages, private suites and build-to-suitROOFTOP
Space availablePOWER AVAILABILITY
AC and DCFIT OUT
Powered shell, infrastructured shell and turn-key -
PEERING EXCHANGES
CLOUD ACCESS
DIVERSITY
Diverse POEs, MDFs and IDFsCROSS CONNECTS
Fiber, copper and coaxialCARRIER AVAILABILITY
See our carrier list -
ACCESS
Key cards and biometric scannersENTRIES
Double mantrapCAMERAS
Perimeter and interior IP-DVRPERIMETER
8' perimeter fence and controlled site accessSECURITY OFFICERS
24x7x365 in-house and on-site security qualified personnel -
UTILITIES
Diverse utility feedsUPS/PDU/RPP
N, N+1, 2N redundancyGENERATORS
N+1 redundancyMECHANICAL
N+1 chillers, cooling towers, CRAHs and chilled water pumps, 100% concurrently maintainableREMOTE HANDS
24x7x365BMS CONTROLS
State-of-the-art mission-critical controls and monitoringUPTIME
100% uptime SLAOPERATIONS
24x7x365 on-site personnelFLOOD PLAIN
Systems above 500-year flood plainFUEL STORAGE
72 hours, on-site with multiple refueling contractsWATER STORAGE
24 hours, on-site -
FLOOR LOADING
Floor 1: 250 lbs./sq. ft., Floor 2: 165 lbs./sq. ft.CLEAR HEIGHT
11' above 36" raised floorCOLUMN SPACING
Floor 1: 24' x 24', Floor 2: 48' x 48'LOADING DOCK
Exterior 4' dock height with levelersHARDENED EXTERIOR
Roof designed to withstand 125 MPH winds, Reinforced interior cross-bracingELEVATORS
Passenger: 7'w x 4'd x 9'h (3,500 lbs.), Freight: 9'w x 11'd x 9'h (10,000 lbs.) -
WORK SPACE
Office space and conference roomsTECH LOUNGE
24x7x365 tech lounge with kitchen, televisions, couches and short-term desk spacePARKING
Secure on-site parking -
POWER UTILITY
Power taken at 26kV to achieve rate reduction and distribution efficiencies, 100% renewable power sourced through wind (Green-e Certifited)ELECTRICAL
High-efficiency UPS systemsCOOLING
Variable speed CRAHs and ultrasonic humidificationCHILLER
Chilled water with evaporative condensing units and chillers for air- and water-side economizationLIFE SAFETY
Dual-interlock pre-action dry-pipe sprinkler systemLIGHTING
Lutron Eco-System lightingMONITORING
RF Code readers for pin-point accuracy of temperature and humidity within customer deployments -